title: "Thermal compensation"
type: "Knowledge"
date: "2022-04-04"
updated: "2026-11-11"
description: "Strainlabs Embedded Systems Engineer Michael Fransson explains how Strainlabs Bolts cope with providing relevant and correct data in varying temperatures."
url: "https://strainlabs.clearagency.ai/news/thermal-compensation"
canonical: "https://strainlabs.clearagency.ai/news/thermal-compensation"
markdown_url: "https://strainlabs.clearagency.ai/news/thermal-compensation.md"
site: "Smart Bolts by Strainlabs"
publisher: "Smart Bolts by Strainlabs"
contact: "contact@strainlabs.com"
language: "en-GB"
breadcrumbs:
  - "Home: https://strainlabs.clearagency.ai/"
  - "News: https://strainlabs.clearagency.ai/news"
  - "Thermal compensation: https://strainlabs.clearagency.ai/news/thermal-compensation"
author: "Bravo"
reading_time_minutes: 2
---

# Thermal compensation

*Knowledge · 4 April 2022 · 2 min read*

> Strainlabs Embedded Systems Engineer Michael Fransson explains how Strainlabs Bolts cope with providing relevant and correct data in varying temperatures.

KNOWLEDGE

Strainlabs Embedded Systems Engineer Michael Fransson explains how Strainlabs Bolts cope with providing relevant and correct data in varying temperatures.

All sensors and electrical components are in some way affected by temperature and changes in temperature. This also applies to the actual bolt. In stress mechanics, an axial force (preload) applied to a bolt can be determined by measuring its elongation. However, it is not only the preload force that affects the elongation – but also the surrounding temperature and temperature changes. This is known as thermal expansion or thermal contraction.

To accurately measure the preload in a bolt the effect on electronics and the bolt elongation caused by thermal variation must be compensated for. The compensation must be accurate, repeatable and with no side effects even in environments with constantly changing temperatures, something that is a key requirement for almost all sensors.

Strainlabs Bolts & thermal effects

Strainlabs sensors measure the temperature every time a bolt preload value is measured. Each Strainlabs Bolt and its components including the PCB is calibrated to ensure that the preload value is correctly compensated for within the specified operating temperature (-30ºC to +70ºC).  Strainlabs Bolts measures preload using a LED-sensor. The measurements would be inaccurate without an efficient compensation for the thermal effect of the steel and the electronical components. In Strainlabs Analytics, the temperature value is plotted on a graph just like the preload measurements.

The diagram illustrates two identical Strainlabs Bolts at a constant preload but at an increasing temperature. One bolt is using Strainlabs thermal compensation features but the other one does not. In a temperature increase from approx. 8 ºC to 23 ºC the measured value for the non-compensated bolt increase by 25% relative to the bolt proof load while the compensated bolt remains at a constant value.

Advantages with thermal compensation & temperature insights

Temperature information is required to accurately measure preload at every data point
Insights is valuable for learnings related to thermal effects and bolt preload analysis
Detecting condition changes (elevated temperature or temperature differences between similar machines) support condition monitoring in addition to the preload data.
Analysing joint behaviour when clamped parts expand or contract due to temperature changes.

Strainlabs Bolts automatically adapt their preload measurement interval at low temperatures to increase battery lifetime.

Michael Fransson, Strainlabs
Previous

A new Graduate School on IndTech

A new Graduate School on IndTech

Next

Tensile strength in Internet of Bolts

Tensile strength in Internet of Bolts

## Discover the Strainlabs solution

Get to know us to learn more about Internet of Bolts, Preload Monitoring and how Strainlabs System can benefit your operations.

This section is a form (“Discover the Strainlabs solution”) that visitors fill in on the web page. It asks for:

- **Name** (required): short text
- **Company** (optional): short text
- **Phone** (optional): short text
- **Work Email** (required): email address
- **Message** (optional): free text

It is sent with the “Send” button and goes to the Smart Bolts by Strainlabs team.

## Related articles

- [How to Measure Bolt Preload](https://strainlabs.clearagency.ai/news/how-to-measure-bolt-preload.md) — Knowledge, 2026-10-01
- [Predictive maintenance: IoT sensors to prevent industrial downtime](https://strainlabs.clearagency.ai/news/predictive-maintenance-iot-sensors.md) — Knowledge, 2025-12-16

## How to cite

Smart Bolts by Strainlabs. “Thermal compensation”. Smart Bolts by Strainlabs, 2022-04-04. https://strainlabs.clearagency.ai/news/thermal-compensation (accessed <date>).

## Company & contact

- **Company:** Smart Bolts by Strainlabs
- **Address:** Strainlabs head office, Stockholm: | Kungsgatan 64, 111 22 Stockholm
- **General enquiries:** [contact@strainlabs.com](mailto:contact@strainlabs.com)
- **Phone:** +46 (0) 46 286 4000
- **About:** Get to know us to learn more about Internet of Bolts, Preload Monitoring and how Strainlabs System can benefit your operations.

---
[View on site](https://strainlabs.clearagency.ai/news/thermal-compensation) · [All News](https://strainlabs.clearagency.ai/news.md) · [Site index for agents (llms.txt)](https://strainlabs.clearagency.ai/llms.txt)